ABC ELECTRONICS VIETNAM CO., LTD
QUALITY MANAGEMENT DEPARTMENT
No. 8D-2026-031
Bắc Ninh, 18 November 2026
MINUTES OF QUALITY PROBLEM-SOLVING MEETING
Complaint KH-1107 · Open circuit at connector, model CX-220
- Time and place:
- 13:30–14:20, 18 November 2026 · Plant 2 meeting room
- Chair · Secretary:
- Mr Park Ji-hoon, Plant Director · Ms Vương Thị Hạnh, quality engineer
- Language:
- English and Vietnamese; English and Korean translations attached
I. Problem description (D2)
The customer found 46 units with an open circuit at the connector in lot 2611-07, a rate of 0.38%.00:04:20to check
II. Containment (D3)
Three related lots quarantined; 100% connector inspection before shipment from 18 November.00:09:45
III. Root cause (D4)
Soldering temperature at station 4 on line SMT-2 below specification after the tip was replaced on 5 November.00:21:30
Shift B's post-maintenance checklist had no temperature check.00:21:52
IV. Corrective actions (D5–D6)
Add a temperature check to the post-maintenance checklist: maintenance, Mr Nguyễn Hữu Phước, by 25 November 2026.00:33:05
V. Preventing recurrence (D7)
Update the SMT-2 FMEA and retrain shift B maintenance: engineering, by 2 December 2026.00:41:50
The customer report is sent in English once these minutes are approved.
SECRETARY
(Signature and full name)
Vương Thị Hạnh
QA MANAGER
(Signature and full name)
Tạ Minh Khôi
PLANT DIRECTOR
(Signature and full name)
Park Ji-hoon